TBTRMR-1C
TBTSCIETECH
Availability: | |
---|---|
Main features:
Only make calibration the board in White to proceed measuring markings in Yellow.
5-inch bright touching screen, real-time display of temperature and humidity.
Real-time voice broadcast in English ofmeasurement data.
Imported detect sensor.
One-button measurement, no need to repeat calibration in the same day.
Long standby time, fast charging.
USB data interface, the test report is exported to computer in form of database.
Optional Bluetooth report printing.
This instrument test result accurate and repeatable, simple to operate, can be used in laboratory or field.
Relative Standards:
GB/T 26377-2010, GB/T 16311-2009, JJG059-2004
Main features:
Only make calibration the board in White to proceed measuring markings in Yellow.
5-inch bright touching screen, real-time display of temperature and humidity.
Real-time voice broadcast in English ofmeasurement data.
Imported detect sensor.
One-button measurement, no need to repeat calibration in the same day.
Long standby time, fast charging.
USB data interface, the test report is exported to computer in form of database.
Optional Bluetooth report printing.
This instrument test result accurate and repeatable, simple to operate, can be used in laboratory or field.
Relative Standards:
GB/T 26377-2010, GB/T 16311-2009, JJG059-2004
Technical Specification:
Measurement items: | retroreflective coefficient ( mcd.m-2.lx-1 ) |
Measurement range: | 0---2000 |
Observation angle: | 1.05° |
Angle of incidence: | 88.76°, complementary angle 1.24° |
Light source color temperature: | 2856±50K |
Repeatability measurement error | ≤2% |
Measuring aperture area: | 340mm x 95mm |
Touching screen | 5" |
Continuous working time of battery: | >30h |
Data storage space: | 100,000 pcs of testing data |
Built-in battery capacity: | 12V, 5.2Ah |
Charger: | DC15V |
Ambient temperature: | -15℃~+60℃ |
Ambient humidity: | <98%, no frost |
interface | USB |
Instrument size: | 700mm x 140mm x 140mm |
Weight | 5KG |
Technical Specification:
Measurement items: | retroreflective coefficient ( mcd.m-2.lx-1 ) |
Measurement range: | 0---2000 |
Observation angle: | 1.05° |
Angle of incidence: | 88.76°, complementary angle 1.24° |
Light source color temperature: | 2856±50K |
Repeatability measurement error | ≤2% |
Measuring aperture area: | 340mm x 95mm |
Touching screen | 5" |
Continuous working time of battery: | >30h |
Data storage space: | 100,000 pcs of testing data |
Built-in battery capacity: | 12V, 5.2Ah |
Charger: | DC15V |
Ambient temperature: | -15℃~+60℃ |
Ambient humidity: | <98%, no frost |
interface | USB |
Instrument size: | 700mm x 140mm x 140mm |
Weight | 5KG |
Configuration:
Host unit ................................................................1 pc
Calibration boards ...............................................1 set (white, black each)
Charger ..................................................................1 pc
USB line.. ...............................................................1 pc
Carry case ..............................................................1 pc
Configuration:
Host unit ................................................................1 pc
Calibration boards ...............................................1 set (white, black each)
Charger ..................................................................1 pc
USB line.. ...............................................................1 pc
Carry case ..............................................................1 pc
content is empty!