TBT-0620B
TBTSCIETECH
Availability: | |
---|---|
This instrument is made as per standards of Dynamic Viscosity Test for Bitumen (Vacuum Capillary Method), also meets SH/T0557-1998 Test method for Viscosity of Petroleum Asphalt (Capillary Method) .
It is used to determine the dynamic viscosity of sticky petroleum asphalts by vacuum capillary viscometer.It is also suitable to determine other materials which viscosity range is 0.0036~20.000Pa.s.
This instrument is made as per standards of Dynamic Viscosity Test for Bitumen (Vacuum Capillary Method), also meets SH/T0557-1998 Test method for Viscosity of Petroleum Asphalt (Capillary Method) .
It is used to determine the dynamic viscosity of sticky petroleum asphalts by vacuum capillary viscometer.It is also suitable to determine other materials which viscosity range is 0.0036~20.000Pa.s.
1.It has a data base for coefficients of capillary viscometers. It can save 10 groups of coefficients at most. Operator can callout the data whenever need.
2.It adopts high accuracy pressure sensor. The vacuum degree can be kept at 300mmHg±0.5mmHg. It can be shown on the screen clearly.
3.The system will ignore the results which timing is less than 60s and enter next measurement step. The system will calculate the viscosity automatically for the results which timing is beyond 60s.
4.Operator can choose and set automatic calculation of average value and bias percentage for 2~4 parallel tests at will.The calculation can be done for several times to remove the unsatisfied results for operator. The test report can be printed.
1.It has a data base for coefficients of capillary viscometers. It can save 10 groups of coefficients at most. Operator can callout the data whenever need.
2.It adopts high accuracy pressure sensor. The vacuum degree can be kept at 300mmHg±0.5mmHg. It can be shown on the screen clearly.
3.The system will ignore the results which timing is less than 60s and enter next measurement step. The system will calculate the viscosity automatically for the results which timing is beyond 60s.
4.Operator can choose and set automatic calculation of average value and bias percentage for 2~4 parallel tests at will.The calculation can be done for several times to remove the unsatisfied results for operator. The test report can be printed.
Temperature control mode | Point controlled by digital temperature controller. |
Temperature control arrange | 0.00℃~100.00℃ |
Temperature control accuracy | ±0.01℃ |
Pressure range | 300mmHg±0.5mmHg |
Timing mode | 4 built-in timer. Can do timing for 4 capillary viscometers |
Timing range | 0.0s~99999.9s (27.7h) Bias ≤0.02% |
Measurement range | About 18 Pa.s~580000Pa.s |
Test samples | 4 samples |
Operation interface | Touch-type colored LCD |
Power supply | AC (220±10%) V , 50Hz |
Ambient temperature | 5℃~50℃ |
Relative humidity | ≤85% |
Overall dimension | 590mm×430mm×630mm |
Net weight | 32.5kg(no water in bath) |
Maximum power consumption | 1800W |
Temperature control mode | Point controlled by digital temperature controller. |
Temperature control arrange | 0.00℃~100.00℃ |
Temperature control accuracy | ±0.01℃ |
Pressure range | 300mmHg±0.5mmHg |
Timing mode | 4 built-in timer. Can do timing for 4 capillary viscometers |
Timing range | 0.0s~99999.9s (27.7h) Bias ≤0.02% |
Measurement range | About 18 Pa.s~580000Pa.s |
Test samples | 4 samples |
Operation interface | Touch-type colored LCD |
Power supply | AC (220±10%) V , 50Hz |
Ambient temperature | 5℃~50℃ |
Relative humidity | ≤85% |
Overall dimension | 590mm×430mm×630mm |
Net weight | 32.5kg(no water in bath) |
Maximum power consumption | 1800W |
No. | Name | Unit | Qty |
1 | Bitumen Dynamic Viscometer | Set | 1 |
2 | Vacuum capillary viscometer type: 50,100,200 Corresponding radius(mm):0.25,0.5,1.0 | Piece | Each 1 |
3 | Mecury thermometer(50℃~100℃;scale mark 0.1℃) | Piece | 1 |
4 | Thermometer silica gel plug(1#) | Piece | 1 |
5 | Capillary clip | Piece | 4 |
6 | Stopping ring of thermometer(1#) | Piece | 4 |
7 | Bath cover | Piece | 4 |
8 | Fuse 10A(Ф5×20) | Piece | 1 |
9 | Silicone tube(External diameter Ф12×thickness2) | Meter | 1 |
10 | Operation manual | Meter | 1 |
11 | Temperature control device usage manual | Meter | 1 |
12 | Quality certificate | Meter | 1 |
13 | Repair guarantee | Meter | 1 |
No. | Name | Unit | Qty |
1 | Bitumen Dynamic Viscometer | Set | 1 |
2 | Vacuum capillary viscometer type: 50,100,200 Corresponding radius(mm):0.25,0.5,1.0 | Piece | Each 1 |
3 | Mecury thermometer(50℃~100℃;scale mark 0.1℃) | Piece | 1 |
4 | Thermometer silica gel plug(1#) | Piece | 1 |
5 | Capillary clip | Piece | 4 |
6 | Stopping ring of thermometer(1#) | Piece | 4 |
7 | Bath cover | Piece | 4 |
8 | Fuse 10A(Ф5×20) | Piece | 1 |
9 | Silicone tube(External diameter Ф12×thickness2) | Meter | 1 |
10 | Operation manual | Meter | 1 |
11 | Temperature control device usage manual | Meter | 1 |
12 | Quality certificate | Meter | 1 |
13 | Repair guarantee | Meter | 1 |
content is empty!