TBT-4508C
Availability: | |
---|---|
TBT-4508C is suitable to determine the distance to which it will elongate before breaking when two ends of a briquette specimen of the material are pulled apart at a specified speed and at a specified temperature.
TBT-4508C is suitable to determine the distance to which it will elongate before breaking when two ends of a briquette specimen of the material are pulled apart at a specified speed and at a specified temperature.
ASTM D113
ASTM D113
1. 10.1 inch 1024×600 coloured touch screen;
2. Full touch screen operation, convenient and fast;
3. High power compressor is adopted for refrigeration, with fast refrigeration speed;
4. 32-bit ARM microcontroller control, automatic display ductility data;
5. Shield type cold heat balance pressurization cycle system, to ensure the temperature in the bath is uniform;
6. Automatically detect and control the water bath’s temperature;
7. Automatically detect and control drag speed;
8. Data storage, easy to query;
9. Automatically calculate and display the average ductility value;
10. Stainless Steel bath with scale ruler;
11. Test three specimen meantime.
1. 10.1 inch 1024×600 coloured touch screen;
2. Full touch screen operation, convenient and fast;
3. High power compressor is adopted for refrigeration, with fast refrigeration speed;
4. 32-bit ARM microcontroller control, automatic display ductility data;
5. Shield type cold heat balance pressurization cycle system, to ensure the temperature in the bath is uniform;
6. Automatically detect and control the water bath’s temperature;
7. Automatically detect and control drag speed;
8. Data storage, easy to query;
9. Automatically calculate and display the average ductility value;
10. Stainless Steel bath with scale ruler;
11. Test three specimen meantime.
Power supply | AC(220±10%)V, 50Hz |
Measurement distance | 1.5m(±10mm) |
Heating mode | Electric heater |
Heating power | 4500W |
Temperature control mode | Shield type cold heat balance pressurization cycle system |
Temperature control range | (5~50)℃, adjustable. Resolution is 0.01℃ |
Temperature control accuracy | ±0.1℃ |
Tensile speed | 10mm/min and 50mm/min, two grades |
Measurement accuracy | ±1 mm |
Ductility display | Display in real time |
Ductility record | By touching screen |
Average ductility | When the ductility record is finished, automatically display in the screen |
Refrigeration mode | Compressor refrigeration |
Ambient temperature | (15~+35)℃ |
Relative humidity | ≤85% |
Dimension | 2370mm×520mm×1000mm |
Total power consumption | ≤5600W |
Net wet | 285kg |
Power supply | AC(220±10%)V, 50Hz |
Measurement distance | 1.5m(±10mm) |
Heating mode | Electric heater |
Heating power | 4500W |
Temperature control mode | Shield type cold heat balance pressurization cycle system |
Temperature control range | (5~50)℃, adjustable. Resolution is 0.01℃ |
Temperature control accuracy | ±0.1℃ |
Tensile speed | 10mm/min and 50mm/min, two grades |
Measurement accuracy | ±1 mm |
Ductility display | Display in real time |
Ductility record | By touching screen |
Average ductility | When the ductility record is finished, automatically display in the screen |
Refrigeration mode | Compressor refrigeration |
Ambient temperature | (15~+35)℃ |
Relative humidity | ≤85% |
Dimension | 2370mm×520mm×1000mm |
Total power consumption | ≤5600W |
Net wet | 285kg |
content is empty!