TBTKVM-265E
TBTSCIETECH
Availability: | |
---|---|
TBTKVM-265D consists of heating stirring system, heating cylinder, electrical control part, and equipped with light source observation, high precision temperature control instrument temperature control.
TBTKVM-265D consists of heating stirring system, heating cylinder, electrical control part, and equipped with light source observation, high precision temperature control instrument temperature control.
SH/T 0654, JTG E20/T 0619, ASTM D2170
SH/T 0654, JTG E20/T 0619, ASTM D2170
1. Intelligent digital display temperature control instrument automatic temperature control, accurate measurement, and has the check function.
2. High temperature resistant heating cylinder, equipped with light source for easy observation.
3. The analytical test of three samples can be carried out simultaneously.
4. The surface of the instrument is corrosion-resistant and the panel is easy to operate.
1. Intelligent digital display temperature control instrument automatic temperature control, accurate measurement, and has the check function.
2. High temperature resistant heating cylinder, equipped with light source for easy observation.
3. The analytical test of three samples can be carried out simultaneously.
4. The surface of the instrument is corrosion-resistant and the panel is easy to operate.
Operating temperature | 135℃ |
Power | 1.6kw |
constant temperature accuracy | ±0.1℃ |
Power supply voltage | 220V |
Dimension | 420×420×660(mm) |
Operating temperature | 135℃ |
Power | 1.6kw |
constant temperature accuracy | ±0.1℃ |
Power supply voltage | 220V |
Dimension | 420×420×660(mm) |
NO | Name | Quantity |
1 | Main Unit | 1 |
2 | Reverse Flow capillary viscometer-- One group of Cannon-Fenske Reverse Flow capillary viscometers; 7 pieces in total. They are N0.200, 300, 350, 400, 450, 500 and 600 (The inner diameters of R tube of them are 1.02, 1.26, 1.48, 1.88, 2.20, 3.10 and 4.00 mm respectively) | 1 |
3 | Mercury thermometer (100~150 ℃, scale division is 0.1℃) | 1 |
4 | Stopping ring for thermometer | 1 |
5 | Bakelite cover | 4 |
6 | Capillary viscometer holder | 4 |
NO | Name | Quantity |
1 | Main Unit | 1 |
2 | Reverse Flow capillary viscometer-- One group of Cannon-Fenske Reverse Flow capillary viscometers; 7 pieces in total. They are N0.200, 300, 350, 400, 450, 500 and 600 (The inner diameters of R tube of them are 1.02, 1.26, 1.48, 1.88, 2.20, 3.10 and 4.00 mm respectively) | 1 |
3 | Mercury thermometer (100~150 ℃, scale division is 0.1℃) | 1 |
4 | Stopping ring for thermometer | 1 |
5 | Bakelite cover | 4 |
6 | Capillary viscometer holder | 4 |
content is empty!