TBTTQ-1J
TBTSCIETECH
Availability: | |
---|---|
Main Features:
5-inch touching screen, real-time display temperature and humidity, Chinese-English switchable.
The incident angle automatically matches the observation angle.
Hollow-out assistant angle board, help to accurately locate incident angle, no need to manually adjust incident & observation angle.
With functions of parameter verification, automatic Zero setting, data storage, export, deletion, and query.
Calibrate all angles in one time.
USB data interface, test report is exported to computer in form of database.
Applicable for laboratory or on-site testing.
Relative Standards:
GB/T 26377-2010
JJG059-2004
GB/T 24725-2009
Main Features:
5-inch touching screen, real-time display temperature and humidity, Chinese-English switchable.
The incident angle automatically matches the observation angle.
Hollow-out assistant angle board, help to accurately locate incident angle, no need to manually adjust incident & observation angle.
With functions of parameter verification, automatic Zero setting, data storage, export, deletion, and query.
Calibrate all angles in one time.
USB data interface, test report is exported to computer in form of database.
Applicable for laboratory or on-site testing.
Relative Standards:
GB/T 26377-2010
JJG059-2004
GB/T 24725-2009
Technical Specification:
Measurement items: | retroreflective coefficient ( mcd.lx-1 ) | ||||
Measurement range: | 0---2000 | ||||
Observation angle: | 0.2° | 0.33° | 1.0° | 2° | 0.2° |
Angle of incidence: | 0° | ±5° | ±10° | ±15° | ±20° |
Light source color temperature: | 2856±50K | ||||
Repeatability measurement error | 5% | ||||
Touching screen | 5" | ||||
Continuous working time of battery: | >30h | ||||
Data storage space: | 500 pcs | ||||
Built-in battery capacity: | 12V 5.2Ah | ||||
Charger: | DC15V | ||||
Ambient temperature: | -15℃~60℃ | ||||
Ambient humidity: | <98%, no frost | ||||
Instrument size: | 330mm x 220mm x 100mm | ||||
Weight | 5.5KG |
Technical Specification:
Measurement items: | retroreflective coefficient ( mcd.lx-1 ) | ||||
Measurement range: | 0---2000 | ||||
Observation angle: | 0.2° | 0.33° | 1.0° | 2° | 0.2° |
Angle of incidence: | 0° | ±5° | ±10° | ±15° | ±20° |
Light source color temperature: | 2856±50K | ||||
Repeatability measurement error | 5% | ||||
Touching screen | 5" | ||||
Continuous working time of battery: | >30h | ||||
Data storage space: | 500 pcs | ||||
Built-in battery capacity: | 12V 5.2Ah | ||||
Charger: | DC15V | ||||
Ambient temperature: | -15℃~60℃ | ||||
Ambient humidity: | <98%, no frost | ||||
Instrument size: | 330mm x 220mm x 100mm | ||||
Weight | 5.5KG |
Configuration:
Main unit ................................................................1 pc
Calibration blocks .................................................2 pcs (white, yellow each)
Incident angle board...............................................3 pcs
Charger ..................................................................1 pc
USB cable ...............................................................1 pc
Carry case ..............................................................1 pc
Configuration:
Main unit ................................................................1 pc
Calibration blocks .................................................2 pcs (white, yellow each)
Incident angle board...............................................3 pcs
Charger ..................................................................1 pc
USB cable ...............................................................1 pc
Carry case ..............................................................1 pc
content is empty!